Kastler-Energy 
Converging Technologies | from Problem to Solution | Fail fast - but intelligently

Blog 

Categories

2024-10-14

Bidirectional Charging of Electric Vehicles: A Holistic View of This Technology on the Vehicle and Its Components

Bidirectional charging (Vehicle-to-Grid, V2G) allows electric vehicles to be used as energy storage, enabling them to not only draw power from the grid but also feed it back into the grid. This technology holds great potential for stabilizing the power grid and promoting the integration of renewable energy sources. However, bidirectional operation poses several technical challenges, particularly regarding the stress on vehicle components, minimizing idle consumption, and ensuring the stability of software and control systems.

V2G .jpg

Stress on Vehicle Components

1. Battery Contactors and Electrical Components Battery contactors and other electrical components are subjected to significantly more stress in bidirectional operation due to more frequent charging and discharging cycles. These contactors, typically designed for 100,000 to 1,000,000 switching operations, may experience reduced lifespan due to the intensive wear. Solutions such as more robust components or smarter charging strategies that minimize unnecessary switching cycles are essential here.
2. Thermal Management Systems Thermal management systems, like coolant pumps, which are typically designed for about 6,000 hours of operation in standard conditions, will need to handle longer operating times of up to 60,000 hours in bidirectional operation. These systems must be built to withstand the additional demands, and adaptive control systems could help optimize their operation, thereby extending their lifespan.

Difference Between AC and DC in Bidirectional Charging

An important distinction in bidirectional charging is whether direct current (DC) is drawn directly from the battery or if alternating current (AC) is used, which requires conversion by the onboard charger. If the onboard charger is used for both AC charging and discharging, its extended operating time must be considered. The onboard charger needs to be designed to withstand the increased demands of frequent bidirectional power flow and ensure reliable longevity. This presents an additional challenge since onboard chargers are usually designed only for charging and must be reinforced or adapted for bidirectional operation.

Optimization of Idle Consumption

In addition to the stress on physical components, idle consumption poses a significant challenge. Electric vehicles in bidirectional operation must remain in constant communication with the grid, leading to energy losses through auxiliary consumers. To ensure high efficiency and low standby consumption, several measures need to be taken:

1. Energy-Efficient Auxiliary Consumers Auxiliary consumers such as control units, coolant pumps, and communication modules must be designed to minimize their power consumption during idle periods. This can be achieved by using energy-saving technologies and components.

2. Intelligent Control Systems Intelligent control systems should optimize the operation of auxiliary consumers, activating them only when needed. For example, adaptive coolant control could be triggered only when necessary to avoid unnecessary energy consumption.

3. Optimized Communication Modules Communication modules are critical since these systems must remain active in standby mode for grid communication. Using power-saving communication chips and enabling modules to enter a sleep mode when not in use can help reduce energy consumption.

Challenges in Software and Control Systems

In addition to the physical and energy optimization of vehicle components, software and control systems must be adapted to meet the demands of bidirectional operation. A frequently overlooked aspect is that the control units and software of electric vehicles are not designed for continuous operation. Many of these systems need to be regularly recalibrated to maintain performance and stability.

1. Regular Recalibration of Control Systems The control units and software modules responsible for energy management and grid communication need to be recalibrated periodically. This is necessary to ensure long-term accuracy and stability, especially when the vehicle frequently charges and discharges in a bidirectional manner. Without regular recalibration, malfunctions could occur that would disrupt operation.

2. Automated Reboot of Control Units Since the software in many vehicles is not designed for continuous operation, it may be necessary to automate the regular reboot of control units. Continuous operation without restarts could lead to software instability and problems with grid communication. Regular, automated reboots could ensure the software remains in optimal condition, which is critical for V2G operations.

Impact on Battery Cell Degradation 

An essential aspect of bidirectional charging is battery cell degradation, which is influenced by factors like charge cycles, temperature, and usage in driving conditions. Although frequent charging and discharging might accelerate cell degradation, it must be considered that V2G operations occur under more controlled conditions. By maintaining stable temperatures and lower stress, as in stationary charging scenarios, the cyclic aging of cells is less pronounced than during driving. This can slow down aging processes, particularly if intelligent charging strategies are implemented, keeping the cells within optimal states of charge (SoC).

Avoiding Extreme Charge/Discharge Rates By avoiding extreme charging and discharging rates, as well as deep discharges or full charges, battery cell life can be significantly extended. Additionally, the more stable thermal environment, which experiences fewer temperature fluctuations compared to driving conditions, reduces thermal stress on the cells. This is important, as temperature swings are one of the main drivers of accelerated battery degradation. Through well-calibrated thermal management and optimized charging strategies, the aging of cells in bidirectional operation can be minimized, allowing for a comparable lifespan to conventional use.

Increased Use of Charging Infrastructure

Another critical aspect of bidirectional charging is the mechanical stress on the charging infrastructure, particularly the charging connector. In regular operation, the charging connector of an electric vehicle is typically used only once or twice per week to recharge the vehicle. In bidirectional charging, where the vehicle not only draws power but also frequently feeds energy back into the grid, the charging connector may be used several times daily.

Effects of More Frequent Use of the Charging Connector:

1. Increased Mechanical Wear More frequent use of the charging connector leads to increased mechanical wear. Components such as contact pins, seals, and locking mechanisms are subjected to faster degradation. The connector, initially designed for a limited number of cycles, may wear out earlier due to intensive use. This not only leads to higher maintenance costs but could also compromise the reliability of the charging connection in the worst case.

2. Higher Durability and Robustness Requirements To meet the demands of bidirectional charging, the charging connector must be made more durable and robust. Potential solutions include:
o Using improved materials for the contact pins to reduce wear and corrosion.
o Enhanced mechanisms for locking and sealing to ensure longevity even with frequent use.

Conclusion

Bidirectional charging of electric vehicles offers tremendous advantages for the energy transition but also introduces technical challenges that must be addressed. In addition to adapting vehicle components to withstand the increased stress, optimizing idle consumption through energy-efficient auxiliary consumers and intelligent controls, the software stability plays a crucial role. Control units and software must be regularly recalibrated and automated reboots may be necessary to ensure continuous operational stability.

Another key issue is the aging of battery cells. Although bidirectional operation requires additional charge and discharge cycles, the cyclical aging of cells is not significantly accelerated due to controlled temperatures and lower stress compared to driving. Optimized charging strategies and effective thermal management can maintain the lifespan of battery cells at a high level.
Only through comprehensive optimization—ranging from mechanical components to software and battery cell aging—can the long-term benefits of bidirectional charging be realized efficiently.

Admin - 11:18:40 @ English | Add a comment